EMC Cable Screw Glands UNI HF Dicht, brass, metric, 13,0 - 9,0 cable, M 20 x 1,5 brass
The functional effect of the gland is only achieved by a low-ohm transition resistance between the cable and line lead-ins and the wall of the electrical unit, i. e. clean the conact surfaces or even better provide permanent bonding frohm inside by fitting lock nuts with equipotential bonding- material: brass, nickel-plated
- material sealing insert: TPE
- protection spec.: IP 68 up to 10 bar
- temperature resistance: -20 °C up to +105 °C
- H [mm]
- 21
- GL [mm]
- 6.5
- min. - max. cable diameter [mm]
- 13 - 9
- Material
- brass nickel-plated
- Screen diameter max.-min. [mm]
- 10.5 - 6.5
- Index
- A
- Thread (AG)
- M 20 x 1,5
- Manufacturer declaration
- Download